{"id":10219,"date":"2024-12-05T13:26:31","date_gmt":"2024-12-05T05:26:31","guid":{"rendered":"https:\/\/timeway-hydraulics.com\/?p=10219"},"modified":"2024-12-05T13:26:31","modified_gmt":"2024-12-05T05:26:31","slug":"what-is-the-reason-for-the-lack-of-pressure-in-the-gear-pump","status":"publish","type":"post","link":"https:\/\/timeway-hydraulics.com\/tr\/what-is-the-reason-for-the-lack-of-pressure-in-the-gear-pump\/","title":{"rendered":"Di\u015fli pompas\u0131ndaki bas\u0131n\u00e7 eksikli\u011finin nedeni nedir?"},"content":{"rendered":"<p><strong>Di\u015fli pompalarda bas\u0131n\u00e7 eksikli\u011finin nedenleri a\u015fa\u011f\u0131dakileri i\u00e7erebilir:<\/strong><\/p>\n\n\n\n<p>1. Yanl\u0131\u015f d\u00f6n\u00fc\u015f y\u00f6n\u00fc: Di\u015fli pompan\u0131n d\u00f6n\u00fc\u015f y\u00f6n\u00fcn\u00fcn belirtilen y\u00f6n\u00fcn tersi olmas\u0131 pompan\u0131n ar\u0131zalanmas\u0131na neden olacakt\u0131r. G\u00fc\u00e7 hatt\u0131n\u0131 ayarlayarak y\u00f6n\u00fc yeniden ayarlayabilirsiniz.<\/p>\n\n\n\n<p>2. Ya\u011f emme boru hatt\u0131 sorunlar\u0131: Gev\u015fek ya\u011f emme boru hatlar\u0131, s\u0131k\u0131\u015fm\u0131\u015f tek y\u00f6nl\u00fc valfler veya yabanc\u0131 cisimler taraf\u0131ndan t\u0131kanm\u0131\u015f emme boru hatlar\u0131n\u0131n t\u00fcm\u00fc di\u015fli pompan\u0131n ya\u011f emme etkisini etkileyebilir. S\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 sa\u011flamak i\u00e7in ya\u011f emme boru hatt\u0131n\u0131 kontrol etmek ve ayarlamak gerekir.<\/p>\n\n\n\n<p>3. Pompa g\u00f6vdesinin zay\u0131f s\u0131zd\u0131rmazl\u0131\u011f\u0131: Bir di\u015fli pompan\u0131n pompa g\u00f6vdesi ve pompa kapa\u011f\u0131 aras\u0131ndaki zay\u0131f s\u0131zd\u0131rmazl\u0131k a\u015f\u0131r\u0131 i\u00e7 bo\u015flu\u011fa neden olabilir, i\u00e7 s\u0131z\u0131nt\u0131y\u0131 art\u0131rabilir ve vakum derecesini d\u00fc\u015f\u00fcrebilir. S\u0131zd\u0131rmazl\u0131\u011f\u0131 zay\u0131f olan par\u00e7alar\u0131n de\u011fi\u015ftirilmesi gerekir.<\/p>\n\n\n\n<p>4. Ya\u011f miktar\u0131 ve s\u0131cakl\u0131k sorunlar\u0131: Ya\u011f deposundaki yetersiz ya\u011f miktar\u0131 veya ya\u011f pompas\u0131 par\u00e7alar\u0131n\u0131n ciddi \u015fekilde a\u015f\u0131nmas\u0131 ve d\u00fc\u015f\u00fck ya\u011f s\u0131cakl\u0131\u011f\u0131n\u0131n neden oldu\u011fu ya\u011f viskozitesindeki azalma, di\u015fli pompas\u0131n\u0131n \u00e7al\u0131\u015fma etkisini etkileyebilir. Ciddi \u015fekilde a\u015f\u0131nm\u0131\u015f par\u00e7alar\u0131n de\u011fi\u015ftirilmesi ve zaman\u0131nda ya\u011f takviyesi yap\u0131lmas\u0131 gerekir.<\/p>\n\n\n\n<p>5. Ya\u011f emme filtresinin t\u0131kanmas\u0131: Ya\u011f emi\u015f filtresinin t\u0131kanmas\u0131 ya\u011f emi\u015f verimlili\u011fini azaltacakt\u0131r ve ya\u011f emi\u015f filtresinin d\u00fczenli olarak temizlenmesi gerekir.<\/p>\n\n\n\n<p>6. Yetersiz sistem y\u00fck\u00fc: Sistem y\u00fck\u00fc pompan\u0131n ihtiya\u00e7 duydu\u011fu bas\u0131nc\u0131 sa\u011flamak i\u00e7in yetersiz oldu\u011funda, di\u015fli pompa d\u00fczg\u00fcn \u00e7al\u0131\u015famaz. Boru hatt\u0131n\u0131 ve vanalar\u0131 ayarlayarak di\u015fli pompan\u0131n y\u00fck bas\u0131nc\u0131n\u0131 artt\u0131rmak gerekir.<\/p>\n\n\n\n<p><strong>\u00c7\u00f6z\u00fcmler \u015funlar\u0131 i\u00e7erir:<\/strong><\/p>\n\n\n\n<p>1. Do\u011fru d\u00f6n\u00fc\u015f y\u00f6n\u00fcn\u00fc sa\u011flamak i\u00e7in g\u00fc\u00e7 devresini ayarlay\u0131n.<\/p>\n\n\n\n<p>2. S\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 sa\u011flamak i\u00e7in ya\u011f emme boru hatt\u0131n\u0131 ayarlay\u0131n.<\/p>\n\n\n\n<p>3. Pompa g\u00f6vdesinin iyi s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 sa\u011flamak i\u00e7in zay\u0131f s\u0131zd\u0131rmaz bile\u015fenleri de\u011fi\u015ftirin.<\/p>\n\n\n\n<p>4. Ciddi \u015fekilde a\u015f\u0131nm\u0131\u015f par\u00e7alar\u0131 de\u011fi\u015ftirin, ya\u011f\u0131 zaman\u0131nda doldurun ve ya\u011f s\u0131cakl\u0131\u011f\u0131n\u0131 normal aral\u0131kta tutun.<\/p>\n\n\n\n<p>5. Ya\u011f emme filtresini t\u0131kanmamas\u0131 i\u00e7in d\u00fczenli olarak temizleyin.<\/p>\n\n\n\n<p>6. Boru hatt\u0131n\u0131 ve vanalar\u0131 ayarlayarak di\u015fli pompan\u0131n y\u00fck bas\u0131nc\u0131n\u0131 artt\u0131r\u0131n.<\/p>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>Di\u015fli pompalarda bas\u0131n\u00e7 eksikli\u011finin nedenleri a\u015fa\u011f\u0131dakileri i\u00e7erebilir: 1. Yanl\u0131\u015f d\u00f6n\u00fc\u015f y\u00f6n\u00fc: Di\u015fli pompan\u0131n d\u00f6n\u00fc\u015f y\u00f6n\u00fcn\u00fcn belirtilen y\u00f6n\u00fcn tersi olmas\u0131 pompan\u0131n ar\u0131zalanmas\u0131na neden olur. G\u00fc\u00e7 hatt\u0131n\u0131 ayarlayarak y\u00f6n\u00fc yeniden ayarlayabilirsiniz. 2. Ya\u011f emme boru hatt\u0131 sorunlar\u0131: ...<\/p>\n<p class=\"read-more\"> <a class=\"\" href=\"https:\/\/timeway-hydraulics.com\/tr\/what-is-the-reason-for-the-lack-of-pressure-in-the-gear-pump\/\"> <span class=\"screen-reader-text\">Di\u015fli pompas\u0131ndaki bas\u0131n\u00e7 eksikli\u011finin nedeni nedir?<\/span> Devam\u0131 \"<\/a><\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"default","ast-global-header-display":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","footnotes":""},"categories":[78],"tags":[],"class_list":["post-10219","post","type-post","status-publish","format-standard","hentry","category-technology"],"_links":{"self":[{"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/posts\/10219","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/comments?post=10219"}],"version-history":[{"count":1,"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/posts\/10219\/revisions"}],"predecessor-version":[{"id":10220,"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/posts\/10219\/revisions\/10220"}],"wp:attachment":[{"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/media?parent=10219"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/categories?post=10219"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/timeway-hydraulics.com\/tr\/wp-json\/wp\/v2\/tags?post=10219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}